Detail Specifications
Body Style:
Multipole-single actuator type
Bushing Length:
Between 0.332 inches and 0.380 inches
Body Length:
Between 1.531 inches and 1.562 inches
Body Width:
Between 1.906 inches and 1.937 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 0.875 inches and 0.906 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.594 inches and 0.656 inches
Switch Contact Arrangement:
Single pole, double throw
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
Between 1.797 inches and 1.828 inches
Mounting Facility Type And Quantity:
1 threaded bushing w/panel seal
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
1.0 amperes ac all locations and 1.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac all locations and 50.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
300.0 ac all locations and 500.0 dc all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.375 inches
Switch Location And Position Designation:
Internal at pole three
Trip Delay Time In Seconds Per Rated Continuous Current:
0.055 at 200 pct all locations and 0.950 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Fungus resistant and hermetically sealed
Switch Terminal Type:
Tab, solder lug
Switch Current Rating And Type In Amps:
0.5 ac and 0.5 dc
Switch Voltage Rating And Type In Volts:
120.0 ac and 50.0 dc
Frequency In Hertz:
400.0 all locations
Unpackaged Unit Weight:
150.0 grams
Test Data Document:
81349-mil-c-39019 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Thread Series Designator:
Unef
Terminal Type And Quantity:
6 wire hook
Specification Data:
81349-mil-c-39019/6 government specification
Item Name:
Breaker,input Mains
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
M39019/06-27
Part Number:
M39019/6-215
Part Number:
M39019/06-215
Part Number:
MIL-PRF-39019
Part Number:
M39019/06-27
Part Number:
M39019/6-215
Part Number:
M39019/06-215
Part Number:
MIL-PRF-39019
Part Number:
M39019/06-27
Part Number:
M39019/6-215
Part Number:
M39019/06-215
Part Number:
MIL-PRF-39019